EMC motor cables - halogen free

TOPDRIVE ROZ1-K (AS) VFD, EMC - 0,6/1 kV

TOPDRIVE® ROZ1-K (AS) VFD EMC is especially suitable for all use where the demand is for double screened cables in connection with EMC. The cable is used in industrial and building installations, in public buildings, power plants, and engine installations or anywhere where there is a demand for 0.6/1 kV screened, halogen free, 90° C cable. The cable is suited for burial and may be used outdoors.

> See products

TOPDRIVE ROZ1-K (AS) VFD, EMC - 0,6/1 (1,2) kV

TOPDRIVE® ROZ1-K (AS) VFD EMC 0.6/1 (1.2) is especially suitable for all use where the demand is for double screened cables in connection with EMC. The cable is used in industrial and building installations, in public buildings, power plants, and engine installations or anywhere where there is a demand for 0.6/1 kV screened, halogen free, 90° C cable. The cable is suited for burial and may be placed outdoors.

> See products

TOPDRIVE ROZ1-K (AS) VFD EMC - 1.8/3 kV

TOPDRIVE ROZ1-K (AS) VFD EMC is especially suitable for all use where the demand is for double shielded cables in connection with EMC. The cable is used in industrial- and building installations, in public buildings, power plants, and engine installations or anywhere where there is a demand for shielded, halogen free, 90° C cable. The cable may be laid directly in the ground.

> See products

TOXFREE Z1C4Z1-K (AS), EMC - 0,6/1 kV

TOXFREE® Z1C4Z1-K (AS), EMC is suitable for all use where there is a demand for screened cables regarding EMC. For use in industry and building installations, public buildings, power plants or anywhere where there is a demand for 0.6/1 kV screened, halogen free cables. The cable is suited for burial and may be placed outdoors.

> See products

TOXFREE RC4Z1-K (AS), EMC - 0,6/1 kV

TOXFREE® RC4Z1-K (AS), EMC is suitable for all use where there is a demand for screened cables regarding EMC. For use in industry and building installations, power plants or anywhere where there is a demand for 0.6/1 kV screened, halogen free cables. The cable is suited for burial and may be placed outdoors.

> See products

SCANFLEX STC Hybrid - 300/500 V

SCANFLEX STC Hybrid is typically used for CTS installations where 2 protective conductors and a flexible and screened cable connection is needed. The cable is oil-resistant, flame retardant, UV-resistant and electromagnetically protected.

> See products

SCANFLEX STC Hybrid - 0,6/1 kV

SCANFLEX STC Hybrid is typically used for frequency converters and CTS installations where 2 protective conductors and a flexible and screened cable connection is needed. The cable is oil-resistant, flame retardant, UV-resistant and electromagnetically protected.

> See products

SCANFIRE EMC 6015 - 0.6/1 kV

SCANFIRE® EMC 6015 is EMC screened and suitable for fixed installation, where there is requirements for power supply during a fire for up to 3 hours (750° C) to motors and ventilators, which are frequency controlled and needs to keep functionality during a fire. F.ex. exhaust fan in an apartment building and exhaust in parking garages.

> See products

TOPDRIVE ROZ1-K (AS+) VFD, EMC - 0,6/1 (1,2) kV

TOPDRIVE ROZ1-K (AS+) VFD EMC 0,6/1 (1,2) kV kablerne er egnede til al anvendelse, hvor der stilles krav om dobbeltskærmede kabler i forbindelse med EMC eller andet. Anvendes inden for industri- og bygningsinstallationer, offentlige byggerier, kraftværker samt motorinstallationer, eller hvor der stilles krav om 0,6/1 kV skærmede halogenfrie 90° C kabler.

> See products

SCANFLEX Servo EMC HFFR Black

Power supply cable for servo motors.

These cables are suited for supply of servo motors for tooling machines, conveyor belts, production units, etc.
The screening of possible pairs for brake and thermal control and overall screening has been optimized in order to minimize electromagnetic interference.

> See products

SCANFLEX STC Hybrid EMC, IEC 60331 - 0,6/1 kV

SCANFLEX STC Hybrid EMC, IEC 60331 is typically used for frequency converters and CTS installations where 2 protective conductors and a flexible and screened cable connection is needed. The cable is oil-resistant, flame retardant, UV-resistant and electromagnetically protected.

> See products

Your contacts

Claus Madsen

Claus Madsen

Sales, Industry/Power/Marine

cm@scankab.dk
+45 6343 1536
Freddy Linde Jensen

Freddy Linde Jensen

Commercial Manager

fj@scankab.dk
+45 6029 7211
Søren Porse

Søren Porse

Country Manager

sp@scankab.dk
+45 2069 7205