SCANFIBER ® Uni MT U-DQ(ZN)BH

Application

Universal cable for permanent installation indoors and outdoors in cable ducts and tubes as well as for direct burial.
Longitudinal and transverse waterproof with a non-metallic rodent protection. High traction and with ripcords that make it easy to open the jacket.

Construction

Cable core

Jelly filled loose tube, outer diameter 2,3 mm with 2-12 optical fibres.

Tube colour: counting tube red, counting direction tube white, other tubes yellow (E9/125) or green (G50/125).
Fiber colour: Acc. to IEC 60304

Outer sheath

FRNC, black, UV-resistant
Wall thickness approx. 1,5 mm.
Two diametrically opposed ripcords under the jacket 

Armour

Multifunctional E-glass yarns wrapped in two layers (left and right spin), as strain relief elements and non-metallic rodent protection.

Technical data

Working temperature

Transport and storage: -40°C to +80°C
Installation: -20°C to +60°C
In use: -40°C to +80°C

Bend radius

10 x cable diameter

Technical comments

Max. tensile force, ST: 5000 N
Max. tensile force, LT: 1600 N
Max. crush resistance, LT: 3000 N/dm, 10 min.
Longitudinally watertight: l=3 m, t=24 h

CPR classification:

Eca

Please request for DoP at dop@scankab.dk
Please request for technical datasheet at fiber@scankab.dk

Approvals

EN 50575, EN 12225, IEC 60304, IEC 60794-1-21 E1, IEC 60794-1-21 E3, IEC 60794-1-21 E4, IEC 60794-1-21 E11A, IEC 60794-1-21 F5A, IEC 60332-1-2, IEC 60332-3-22 Cat. A, IEC 61034, IEC 60754-1, IEC 60754-2, IEC 60794-1-22 F14, IEC 60794-2, CE, RoHS
Bending radius 10 x cable diameter
Can be buried
Can lay in tubes
Fire retardant acc. to IEC 60332-3-22 (CAT-A)
Flame retardant acc. to IEC 60332-1
Halogen free
Low emission of corrosive gases acc. to IEC 60754
Low smoke emission during fire acc. to 61034
Max. working temp. +80° C
Min. working temperature -40° C
Rodent protected
UV-resistant
Water resistant
SKU EAN CPR Dimension (mm2) Current Value (A) Packaging Diameter (mm)* Weight (kg/km)*
8415124OS21032 5704403200566 Eca 24xOS2 (G652D) - D./Cut 11,2 130
8415136OS21033 5704403200573 Eca 36xOS2 (G652D) - D./Cut 11,2 130
8415148OS21034 5704403200580 Eca 48xOS2 (G652D) - D./Cut 11,2 130
8415172OS21035 5704403200597 Eca 72xOS2 (G652D) - D./Cut 11,6 140
8415196OS21036 5704403200603 Eca 96xOS2 (G652D) - D./Cut 13,1 175
84151144OS21037 5704403200610 Eca 144xOS2 (G652D) - D./Cut 16,0 240
8415124OS21038 5704403200627 Eca 24xOS2a (G657A2) - D./Cut 11,2 130
8415136OS21039 5704403200634 Eca 36xOS2a (G657A2) - D./Cut 11,2 130
8415148OS21040 5704403200641 Eca 48xOS2a (G657A2) - D./Cut 11,2 130
8415172OS21041 5704403200658 Eca 72xOS2a (G657A2) - D./Cut 11,6 140
8415196OS21042 5704403200665 Eca 96xOS2a (G657A2) - D./Cut 13,1 175
84151144OS21043 5704403200672 Eca 144xOS2a (G657A2) - D./Cut 16,0 240
8415124OM31044 5704403200689 Eca 24xOM3 - D./Cut 11,2 130
8415136OM31045 5704403200696 Eca 36xOM3 - D./Cut 11,2 130
8415148OM31046 5704403200702 Eca 48xOM3 - D./Cut 11,2 130
8415172OM31047 5704403200719 Eca 72xOM3 - D./Cut 11,6 140
8415196OM31048 5704403200726 Eca 96xOM3 - D./Cut 13,1 175
84151144OM31049 5704403200733 Eca 144xOM3 - D./Cut 16,0 240
8415124OM41050 5704403200740 Eca 24xOM4 - D./Cut 11,2 130
8415136OM41051 5704403200757 Eca 36xOM4 - D./Cut 11,2 130
8415148OM41052 5704403200764 Eca 48xOM4 - D./Cut 11,2 130
8415172OM41053 5704403200771 Eca 72xOM4 - D./Cut 11,6 140
8415196OM41054 5704403200788 Eca 96xOM4 - D./Cut 13,1 175
84151144OM41055 5704403200795 Eca 144xOM4 - D./Cut 16,0 240
8415124OM51056 5704403200801 Eca 24xOM5 - D./Cut 11,2 130
8415136OM51057 5704403200818 Eca 36xOM5 - D./Cut 11,2 130
8415148OM51058 5704403200825 Eca 48xOM5 - D./Cut 11,2 130
8415172OM51059 5704403200832 Eca 72xOM5 - D./Cut 11,6 140
8415196OM51060 5704403200849 Eca 96xOM5 - D./Cut 13,1 175
84151144OM51061 5704403200856 Eca 144xOM5 - D./Cut 16,0 240
* The values can have small deviations