SCANFIBER ® Indoor MT I-F(ZN)HH

Application

Indoor gel-free cable for installation in cable ducts and in tubes. Each fiber is a sub-cable (breakout) with a good buffer protection with aramid, and individual jacket.
For direct connector assembly.

Construction

Cable core

Break-Out sub cables and if necessary, fillers stranded in layers around a central strength member (FRP). (Number of sub cables 2-12)
12 optical fibres (E9/125, G50/125)
Fiber colour: Acc. to IEC 60304
FRNC, Yellow
Wall thickness approx. 0.5 mm

Outer sheath

FRNC, yellow.
Ripcord under the jacket.

Strain relief

Strain relief elements aramid.

Technical data

Working temperature

Transport and storage: -25°C to +70°C
Installation: -5°C to +50°C
In use: -10°C to +70°C

Bend radius

Fixed: 15 x cable diameter
During installation: 20 x cable diameter

Technical comments

Max. crush resistance, LT: 1000 N/dm

CPR classification:

Dca-s2, d2, a1

Please request for DoP at dop@scankab.dk
Please request for technical datasheet at fiber@scankab.dk

Approvals

EN 50575, IEC 60304, IEC 60794-1-2 E11A, IEC 60794-1-2 E6, IEC 60794-1-2 E3, IEC 60794-1-2 F1, IEC 60332-1-2, IEC 60332-3-22 Cat. A, IEC 61034, IEC 60754-1, IEC 60754-2, IEC 60794-2, CE, RoHS
Bending radius 20 x cable diameter
Can lay in tubes
Fire retardant acc. to IEC 60332-3-22 (CAT-A)
Flame retardant acc. to IEC 60332-1
Halogen free
Low emission of corrosive gases acc. to IEC 60754
Low smoke emission during fire acc. to 61034
Max. working temp. +70° C
Min. working temperature -10° C
SKU EAN CPR Dimension (mm2) Current Value (A) Packaging Diameter (mm)* Weight (kg/km)*
8415324OS21140 5704403201433 Dca-s2,d2,a1 24xOS2 - D./Cut 8,9 70
8415348OS21141 5704403201440 Dca-s2,d2,a1 48xOS2 - D./Cut 8,9 70
8415396OS21142 5704403201457 Dca-s2,d2,a1 96xOS2 - D./Cut 13,1 155
84153144OS21143 5704403201457 Dca-s2,d2,a1 144xOS2 - D./Cut 15,4 195
* The values can have small deviations