PT -HF halogen free signal cable - signalkabel

Application

PT-HF halogen free signal cables are used as tele- signal- and alarm cables in low voltage systems.

Construction

Conductor

Solid, tinned Cu wire (Ø. 0.6 mm)

Insulation

Ø 1,10 mm PE (EN 50290-2 / VDE 0207-2YI1)

Conductor color

CN-1

Outer sheath

Halogen free, flame retardant, rip cord, white, blue, black and brown are UV resistant.

Technical data

Working temperature
Flexible: -5° C to +50° C
Fixed:  up to +70° C
Rated voltage

50 V AC
75 V DC

Bend radius

12 x cable diameter

Technical comments

Conductor resistance (core): < or = 67,9 Ohm/km
Insulation resistance: > 1,5 GOhm/km
Mutual capacitance (800 Hz): < or = 80 nF/km.
Capacitance unbalance (800 Hz): < or = 400 pF/500 m

Approvals

EN 50290-2 / VDE 0207-HM2, CE, RoHS
Bending radius 12 x cable diameter
For use in homes
Halogen free
Max. working temp. +70° C
Meter marked
Outdoor use
UV-resistant
SKU EAN Dimension (mm) Current Value (A) Packaging Diameter (mm)* Weight (kg/km)*
406010206 5704403044801 1x2x0,6 - D./Cut 3,25 13
406010216 5704403045464 1x2x0,6 - D./Cut 3,25 13
406010226 5704403053285 1x2x0,6 - D./Cut 3,25 13
406020206 5704403044764 2x2x0,6 - D./Cut 5,40 30
406020216 5704403045471 2x2x0,6 - D./Cut 5,40 30
406020236 5704403051052 2x2x0,6 - D./Cut 5,48 30
406030206 5704403044771 3x2x0,6 - D./Cut 5,60 36
406030216 5704403045488 3x2x0,6 - D./Cut 5,60 36
406030236 5704403051069 3x2x0,6 - D./Cut 5,60 36
406040206 5704403044788 4x2x0,6 - D./Cut 6,00 42
406040216 5704403045495 4x2x0,6 - D./Cut 6,00 42
406040236 5704403051076 4x2x0,6 - D./Cut 6,00 42
406060206 5704403044795 6x2x0,6 - D./Cut 7,05 57
406060216 5704403045501 6x2x0,6 - D./Cut 7,05 57
* The values can have small deviations