DeviceNet Bus H 3005 - 30 V

Application

This DeviceNet cable for fixed installation is designed to operate on two CAN RS 485 connection systems. Standard DeviceNet regulations require a cable with two screened pairs and two different connections types, Trunk and Drop, for data transmission and devices supply. 

Construction

Conductor

Bare copper according to CEI EN 60228 (CEI 20-29) class 5

Insulation

Power - AWG 15 el. AWG 22: Polyolefin
Signal - AWG 18 el. AWG 24: Foam polyolefin

Conductor color

Power - AWG 15 el. AWG 22: Red and black
Signal - AWG 18 el. AWG 24: Light blue and white

Screen

Tinned copper wire braid.
Coverage above 85%.
Pair screening: Aluminium/polyester tape on each pair and common drain wire

Outer sheath

Halogen free class 43 according to UL 1581.
Colour: violet RAL 4001

Technical data

Working temperature

Fixed installation: -30oC to +80oC
Flexible installation: -5oC to +80oC

Rated voltage

30 V

Test voltage

1000 V

Bend radius

Fixed installation: 6 x cable diameter
Flexible installation: 12 x cable diameter

Approvals

CEI EN 60228, UL 1581, UL 758, FT-1 CSA test C.22.2 nr. 210, IEC CEI EN 60332-1, ≤18% IEC 60754, CEI EN 50267-2, DESINA registered, UL/CSA- registered: 80 oC 1000V style 21179, CE
Abrasion resistant
Bending radius 6 x cable diameter
Electromagnetically protected
Flame retardant acc. to IEC 60332-1
Halogen free
Low emission of corrosive gases acc. to IEC 60754
Max. working temp. +80° C
Min. working temperature -30° C
Oil resistant
Water resistant
SKU EAN Dimension (mm) Current Value (A) Packaging Diameter (mm)* Weight (kg/km)*
781015002H 5704403043354 (2xAWG18)+(2xAWG15) TRUNK - Tr./Afklip 11,8 202,5
781034002H - (2xAWG24)+(2xAWG22) DROP - Tr./Afklip 6,9 79,5
* The values can have small deviations